New Aftermarket Cartridge for Eaton Vickers V Series Single Pump 35V Available

$98

This Single Pump Cartridge Kit is designed for Eaton Vickers Vane Pump 35V Cartridge replacement.

Features

  • This Vane Pump is designed for medium pressure multiple industrial applications.
  • Easy to replace without removing the pump from its mounting in 10 minutes.
  • Intra-vane cartridge design with 10 vanes provides long operating life, outstanding volumetric efficiency up to 90%, and excellent serviceability.
  • The super-quiet as low as 62 dB(A), ideal for the indoor industrial environment.

Options

  • Note *

  • Cartridge *

  • Series *

  • Displacement *

  • Design Number *

  • Direction of Rotation *

There are varieties of displacement selections for this vane pump cartridge from 67,0 to 143,0 ml/rev. The max pressure can support up to 210 bar for the instance use case. Also, The rotation speed supports from 600 to 2500 r/min using the different oil types.This vane pump allows low flow at high pressure and high flow at lower pressure. A clever way to optimize your circuit design and to sustain consistency power and flow. This pump also provides fast pressure cycle change with a precise flow.

Here are links for Single Pump Cartridge kit:

20-VQ

25-VQ

35-VQ

45-VQ

20V

25-V

35-V

45-V

Vane Pump Cartridge More Features & Benefits:
  • Reduced energy consumption: Up to 90% Efficiency; reduces heat generation.
  • Low noise level: Optimized for the lowest noise level in the smallest envelope.
  • Increased lifetime: Double lip vane design raises dirt resistance to increase lifetime.
  • Easy installation: Use the same body for all displacements. The port orientation allows customized installation.
Applications:
  • Presses
  • Lubrication
General Applications Instructions:
  • Check speed range, pressure, temperature, fluid quality, fluid viscosity, and pump rotation.
  • Check the inlet conditions of the pump, if it can accept the application requirements.
  • Check the type of shaft: if it will support the operating torque.
  • Check the coupling to cut pump shaft load (weight, misalignment).
  • Filtration: must be adequate for the lowest contamination level.
  • Check the environment of the pump: avoid noise reflection, pollution, and shocks.
Start-up :
  • Fill the tank up with a clean fluid in proper conditions.
  • We recommend flushing the system with an external pump before the start-up.
  • It is important to bleed the air off the circuit & the pump itself.
  • The first valve on the circuit should be open to the tank.
  • We recommend the use of air bleed-off valves.It is possible to bleed off the air by creating a leak in the P port of the pump.
More:
  • We stock replacement parts for our VQ and V series aftermarket line.
  • We are expanding our product range, so please check back often for our new product offering.
  • If you have special requests, feel free to contact us. By the way, we have a strong project team for customized requirements.
Weight 7 kg
Note

F3 – Viton seals, Omit – if not required

Cartridge

Single Pump Kit

Series

35V

Displacement

21, 25, 30, 32, 35, 38, 45

Direction of Rotation

L = Counter-clockwise, R = Clockwise

Design Number

10

Reviews

There are no reviews yet.

Be the first to review “New Aftermarket Cartridge for Eaton Vickers V Series Single Pump 35V Available”

Your email address will not be published. Required fields are marked *

How can we help?

We reply in 24 hours.